LDQ-98A-W Wireless Electromagnetic Water Flow Meter

Wireless Electromagnetic Flow Meter LDQ-98A-W

The LDQ-98-W Wireless Electromagnetic Flowmeter is a product specially designed and developed for measuring clean water and wastewater at oilfield wellheads. It is used for pulsating flow measurement in injection plug pumps at water distribution rooms. This product features stable measurement, high accuracy, and long service life. It is widely applied in petrochemical, petroleum, water supply and drainage, water injection, and dosing systems.

Get A Quote
Detail

The LDQ-98A Series Electromagnetic Flow Meter is a velocity-type instrument based on Faraday’s Law of Electromagnetic Induction, designed to measure the volumetric flow rate of conductive media in pipelines. It consists of two main components: an electromagnetic flow sensor and a converter. This series is capable of measuring clean water, wastewater, corrosive media (e.g., acids, alkalis, and salts), and slurry-type conductive liquids.

The converter employs microcontroller-based embedded technology to achieves digital excitation and provides real-time parameters display (including instantaneous flow, cumulative flow, flow velocity, and flow percentage). Additionally, it supports multiple signal outputs such as frequency, current, and wired/wireless communication, enabling remote monitoring and measurement of flow data.

This product series features stable measurement, high accuracy, and long service life, making it widely applicable in petrochemical, petroleum, water supply and drainage, water injection, and chemical dosing systems.

Measurement Principle:Faraday’s Law of Electromagnetic Induction.

When a conductive liquid moves through a magnetic field and cuts the magnetic lines of flux, it generates an induced electromotive force (EMF), expressed as:

EMF=KBVD

Where:

K: Instrument constant

B: Magnetic flux density

V: Average flow velocity within the measuring tube

D: Inner diameter of the measuring tube

During flow measurement, the fluid passes through a magnetic field perpendicular to the flow direction. The conductive liquid induces a voltage proportional to the average flow velocity (i.e., volumetric flow rate). Therefore, the measured liquid must have a minimum conductivity (>5μS/cm). The induced voltage signal is detected by two electrodes in direct contact with the liquid, transmitted via cable to an amplifier, and converted into a standardized output signal.

Key Advantages of This Measurement Method:

1.The measurement tube contains no flow-obstructing internals, effectively eliminating ancillary pressure losses.

2.Since the measurement result is independent of physical parameters such as liquid pressure, temperature, density, viscosity, and conductivity (>5μS/cm), and the sensor signal is an electromotive force (EMF) that maintains an exact linear relationship with average flow velocity, the measurement demonstrates high accuracy and reliable operation.

3.Since the signal is generated within the fully magnetized space and represents an average value across the pipe cross-section, the sensor requires relatively short straight pipe sections, specifically 5 times the nominal pipe diameter (5DN).

4.As only the pipeline and electrodes of the electromagnetic flowmeter come into contact with the measured liquid, corrosion and wear resistance requirements can be met by appropriately selecting electrode and pipeline lining materials.

Electromagnetic Flow Meter Selection

Model Coding:

Electromagnetic Flowmeter Model Selection Code Cross-Reference Table
A Product Type 1—LDQ-98A-D
2—LDQ-98A-W
3—LDQ-98A-P
4—LDQ-98A-G
5—LDQ-98A-T
B Installation Method Y—Integrated Installation
F—Split Installation
C Sensor Diameter 10—010 50—050 200—200 500—500 1000—102
15—015 65—065 250—250 600—600 1200—122
20—020 80—080 300—300 700—700 1400—142
25—025 100—100 350—350 800—800 1600—162
32—032 125—125 400—400 900—900 1800—182
40—040 150—150 450—450   2000—202
D Electrode Material A—316L Stainless Steel
B—Hc
C—Hb
D—Ti
E—Ta
F—Pt
E Lining Material A—Polytetrafluoroethylene (PTFE, F4)
B—Fluorinated Ethylene Propylene (FEP, F46)
C—Ceramic
D—Chloroprene Rubber (CR)
E—Polyurethane (PU)
F—Fluoroplastic (FS)
F Medium Temperature 1—≤100℃
2—≤120℃
3—≤180℃
4—≤65℃
5—≤80℃
6—≤60℃
G Power Supply 1—220VAC
2—24VDC
3—3.6VDC
H Ambient Temperature 1—-10℃~45℃
2—-20℃~55℃
3—-30℃~80℃
I Converter Installation Orientation A—Type A
B—Type B
C—Type C
J Output Signal 1—Frequency 5000Hz  4~20mA(+HRAT)
2—Frequency 5000Hz  4~20mA
RS485/MODBUS
3—Frequency 5000Hz  4~20mA Other communication standards can be agreed upon
K Grounding Ring 0—No Grounding Ring
1—Grounding Ring
2—Wrapped Grounding Ring
L Ingress Protection 1—IP 54
2—IP 65
3—IP 67
4—IP 68
M Ex-protected design O—Standard Type
E—Explosion-proof Type
N Nominal Pressure(MPa) Directly enter the Nominal Pressure value
O Flow Range Directly enter the minimum and maximum values
A—Horizontal B—Vertical Left C—Vertical Right

 

Technical Parameters

Overview:

The LDQ-98-W Wireless Electromagnetic Flowmeter is a product specially designed and developed for measuring clean water and wastewater at oilfield wellheads. It is used for pulsating flow measurement in injection plug pumps at water distribution rooms. This product features stable measurement, high accuracy, and long service life. It is widely applied in petrochemical, petroleum, water supply and drainage, water injection, and dosing systems.

Features:

1.Employs Zigbee wireless communication technology.

2.Provides self-diagnosis for user convenience.

3.Features high stability and measurement accuracy (up to ±0.5%).

4.Excellent anti-interference performance, with electrostatic and lightning surge voltage resistance ≥1500V.

5.Low power consumption design: two 3.6V lithium batteries ensure a battery life of over 2 years, and battery replacement is effortless.

6.Equipped with an external power supply interface, compatible with 24VDC external power sources.

Specification:

Nominal Diameter DN25~DN50
Nominal Pressure 16MPa、25MPa、32MPa
Ingress Protection IP65
Electrode Material 316L Stainless Steel, Hastelloy C, Ti
Suitable Media Water, Wastewater
Medium Conductivity >5μS/cm
Turndown Ratio 1:10, 1:20, 1:30
Accuracy ±0.5%, ±1.0%
Lining Material FEP (F46)
Medium Temperature -10℃~120℃
Ex-protected design Ex d ib mb ⅡC T5 Gb
Pulse Signal 0~5kHz
Signal Transmitter Module

Frequency Range: 2400~2483.5MHz

Gain: ≥2dBi

Polarization: Linear

Radiation Pattern: Omnidirectional

Connection Type: MMCX (Customizable)

Transmission Distance: ≥200m

(In Unobstructed Line of Sight Conditions)

Output Signal Zigbee, A11-GRM, RS485(MODBUS)
Power Supply M20×1.5 Internal Thread (M18×1.5 Internal Thread, 1/2 NPT Internal Thread, are customizable)
Power Supply Built-in 3.6 V Li-battery (2+ years life, local display only, no output), 24 V DC±5%, 12 V DC±20%(Solar Photovoltaic)
Ambient Temperature -40℃~55℃(requires protective measures below this threshold)
Ambient Humidity 5%~95%

Note: The instrument flanges comply with GB/T 9115-2010. For special requirements, the applicable standard must be specified (ASME B16.5-2009 Pipe Flanges and Flanged Fittings or the Ministry of Chemical Industry standard HG/T 20615-2009 Steel Pipe Flanges (Class Series)).

Installation Size:

 

Nominal Diameter(mm) Flow Range(m³/h) Nominal Pressure(MPa) Overall Dimensions(mm) Flange Dimensions(mm)
L H D1 D D0 n×A Y f C
25 0~7 16 220 500 130 140 100 4×18 58 4 24
25 0~11 25 220 500 130 150 105 4×22 58 4 28
25 0~20 32 240 500 130 160 115 4×22 58 4 34
32 0~7 16 230 505 138 155 110 4×22 66 4 28
32 0~13 25 230 505 138 165 120 4×22 66 4 32
32 0~25 32 240 505 138 175 130 4×26 66 4 36
40 0~7 16 230 508 146 170 125 4×22 76 4 28
40 0~20 25 230 508 146 185 135 4×26 76 4 34
40 0~30 32 260 508 146 195 145 4×26 76 4 38
50 0~10 16 240 514 158 195 145 4×26 88 4 30
50 0~25 25 250 514 158 200 150 8×26 88 4 38
50 0~40 32 280 514 158 210 160 8×26 88 4 42

 

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.