YSB3351D Remote Seal Capillary Flange level Transmitter

Remote Seal Capillary Flange Transmitter YSB3351D

The Remote Seal Capillary Flange Transmitter YSB3351D is designed for process industry applications, capable of measuring pressure and differential pressure of liquids, steam, and gases. Its direct contact with the medium, high-temperature resistance, and easy-to-clean design extend the transmitter’s service life. A comprehensive range of material options is available for users, including stainless steel, Hastelloy, Monel, and tantalum, while the diaphragm can be gold-plated stainless steel, ensuring compatibility with nearly all media. Widely applied in industries such as petroleum, chemical, power generation, food, and pharmaceuticals.

Get A Quote
Detail

The Remote Seal Capillary Flange Transmitter YSB3351D is designed for process industry applications, capable of measuring pressure and differential pressure of liquids, steam, and gases. Its direct contact with the medium, high-temperature resistance, and easy-to-clean design extend the transmitter’s service life. A comprehensive range of material options is available for users, including stainless steel, Hastelloy, Monel, and tantalum, while the diaphragm can be gold-plated stainless steel, ensuring compatibility with nearly all media. Widely applied in industries such as petroleum, chemical, power generation, food, and pharmaceuticals.

Range

0~10kPa, 0~100kPa, 0~500kPa, 0~7MPa (The maximum static pressure reaches 35MPa.)

Ingress Protection

IP65, IP66, IP67

Accuracy

±0.075%, ±0.2%, ±0.5%

Diaphragm Material

316L Stainless Steel, Hastelloy, Ta

Housing Material

Polyurethane Baking Paint-Coated Cast Aluminum Alloy

Suitable Media

Liquid, Gas, Steam

Turndown Ratio

100:1

Media Temperature

-40℃ ~ 120℃

Ex-protected design

Ex d ⅡC T4~T6 Gd、Ex ia ⅡC T6 Ga

Output Signal

4~20mA, 4~20mA+HART

Process Connection

Direct Connectioned: M20×1.5 External Thread or 1/2NPT External Thread.

Pipe Connectioned: 1/2NPT Internal Thread.

Electrical Interface

M20×1.5 Internal Thread or 1/2NPT Internal Thread Two connection port

Power Supply

24VDC±10%

Ambient Temperature

-30~80℃(Including LCD Display Unit), -40~85℃(Requires Protective Measures Below This Threshold)

Ambient Humidity

5~100%RH@40℃

Instrument Stability

15 years±0.2%URL

Mounting Bracket

304 Stainless Steel Horizontal Bracket or Vertical Bracket (Optional)

 

Technical Parameters

DN

d₁

D

D₁

D₂

d

Screw Hole

Insertion Flange

Insertion Dept

Theoretical Weight of Flange

Machine Std.

National Std.

Diameter

Quantity

Screw

50

61

155

165

125

95

20

18

4

M16

50

100

150

2.56Kg

80

78

195

200

160

127

20

18

8

M16

50

100

150

5.00Kg

100

96

230

235

190

156

24

22

8

M20

50

100

150

7.62Kg

Note: Other flange specifications, insertion depth, and implementation standards can be customized according to user requirements.

 

Remote Seal Capillary Flange Transmitter Selection

Model Coding:

Type

Specification Code

Instructions

YSB3351D-

Remote Seal Capillary Flange Transmitter

Product Type

1

 

 

 

 

 

 

 

 

 

 

 

 

Single Remote Seal, Flat Diaphragm

2

 

 

 

 

 

 

 

 

 

 

 

 

Single Remote Seal, Convex Diaphragm

3

 

 

 

 

 

 

 

 

 

 

 

 

Dual Remote Seal, Flat Diaphragm

4

 

 

 

 

 

 

 

 

 

 

 

 

Dual Remote Seal, Convex Diaphragm

5

 

 

 

 

 

 

 

 

 

 

 

 

Combination Remote Seals (Flat + Convex)

Flange Size

1

 

 

 

 

 

 

 

 

 

 

 

1-inch (DN40)

2

 

 

 

 

 

 

 

 

 

 

 

2-inch (DN50)

3

 

 

 

 

 

 

 

 

 

 

 

3-inch (DN80)

4

 

 

 

 

 

 

 

 

 

 

 

4-inch (DN100)

X

 

 

 

 

 

 

 

 

 

 

 

Customizable

Diaphragm Protrusion Length

X0

 

 

 

 

 

 

 

 

 

 

0 mm

X1

 

 

 

 

 

 

 

 

 

 

50 mm

X2

 

 

 

 

 

 

 

 

 

 

100 mm

X3

 

 

 

 

 

 

 

 

 

 

150 mm

X4

 

 

 

 

 

 

 

 

 

 

200 mm

Output Signal

H

 

 

 

 

 

 

 

 

 

4~20 mA

F

 

 

 

 

 

 

 

 

 

4~20 mA + HART

Capillary Length

Direct digital representation (e.g., 05 = 5m), specified capillary length from 1~12m.

Wetted Parts Material

 

 

 

 

 

 

 

 

Diaphragm

Related Connectors

S

 

 

 

 

 

 

 

SUS316L

SUS316

H

 

 

 

 

 

 

 

Hastelloy C-276

Hastelloy C-276

C

 

 

 

 

 

 

 

Monel

Monel

A

 

 

 

 

 

 

 

Gold Plated

SUS316

Low Pressure Side Piping Connection

1

 

 

 

 

 

 

Flange Direct Mount

2

 

 

 

 

 

 

With 1/2 NPT Internal Thread

Electrical Interface

1

 

 

 

 

 

M20×1.5 Internal Thread Two connection port

2

 

 

 

 

 

1/2~14NPT Internal Thread Two connection port

Display Unit

N

 

 

 

 

No Display Unit

D

 

 

 

 

LCD Digital Display Unit

Bracket installation method

A1

 

 

 

Horizontal Bracket

A2

 

 

 

Vertical Bracket

Ex-protected design

B

 

 

Intrinsic Safety (Ex ia ⅡC T6 Ga)

D

 

 

Flameproof Enclosures (Ex d ⅡC T4~T6 Gd)

Accuracy, Range, Range, Implementation Standard

Fill in directly

Additional Options

Special requirements can be agreed upon

 

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
X GET A METERS SOLUTION TODAY!
Inquiry